CS-580 |
CS-600 |
CS-610 |
CS-650 |
CS-660 |
||||
Illumination |
d/8(Diffused lighting, 8 degrees observe angle)、SCI(specular reflection included)/SCE(specular reflection excluded)simultaneous measurement。(conform to CIE No.15,ISO 7724/1,ASTM E1164,DIN 5033 Teil7, JIS Z8722 Condition c standards) |
|||||||
Size of integrating sphere |
Φ40mm,Avian diffused reflection surface coating |
|||||||
Illumination Light source |
CLEDs(entire wavelength balanced LED light source) |
Xenonlamp |
CLEDs |
|||||
Sensor |
dual light path sensor array |
|||||||
Wavelength range |
400-700nm |
360-740nm |
400-700nm |
|||||
Wavelength interval |
10nm |
|||||||
Half spectral width |
5nm |
|||||||
Reflectivity range |
0-200% |
|||||||
Reflectivity resolution |
0.01% |
|||||||
Observation angle |
2°/10° |
|||||||
Measurement light source |
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF |
|||||||
Data being displayed |
Reflectancechart/data,sample's color values,color difference values/graph,pass/fail results,color error tendency,color simulation,display measurement area,history data color simulation,manual input standard sample,generate measurement report |
|||||||
Measurement time interval |
2 seconds |
0.5 seconds |
2 seconds |
0.5 seconds |
||||
Measurement time |
1 second |
|||||||
Color space |
CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance |
|||||||
|
Hunterlab,Munsell MI,CMYK, ,RGB,HSB |
|||||||
Color difference formulas |
ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94,ΔE*00 |
|||||||
|
ΔEab(Hunter),555 color shade |
|||||||
Other colorimetric indices |
WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby); YI(ASTM D1925,ASTM E313-00,ASTM E313-73);Tint(ASTM E313,CIE,Ganz); Metamerism index Milm, Stick color fastness, Color fastness |
|||||||
|
ISO luminance, 8 gloss, A density, T density,M density,E density |
|||||||
Repeatability |
light splitting reflectivity:standard deviation within 0.08% |
|||||||
color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals), Maximum:0.05 |
color values:ΔE*ab<=0.02, Maximum:0.04 |
color values: ΔE*ab<=0.015 Maximum:0.03 |
||||||
Battery capacity |
rechargeable, 10000 continuous tests, 7.4V/6000mAh |
|||||||
Test Aperture |
Type A: 10mm, Type B: 4mm, 6mm |
|||||||
Interface |
USB |
|||||||
Data storage |
20000 test results |
|||||||
Light source longevity |
5 years, 1.5 million tests |
|||||||
Inter-instrument agreement |
ΔE*ab within 0.2(BCRA color charts II, average of the 12 charts) |
|||||||
Size |
181*73*112mm(L*W*H) |
|||||||
Weight |
about 550g(does not include battery's weight) |
|||||||
Display |
True color screen that includes all colors |
|||||||
Work temperature range |
0~45℃, relative humidity 80% or below( at 35°C ),no condensation |
|||||||
Storage temperature range |
-25℃ to 55℃,relative humidity 80% or below(at 35°C ),no condensation |
|||||||
Standard accessories |
DC adapter, Lithium battery, manual, color management software, drive software, electronic manual, color management guide, USB cable, black/white calibration tube, protective cover, spire lamella, portable bag, electronic color charts, measurement and test report |
|||||||
Optional accessories |
powder molding device, micro printer |
|||||||
UV light source |
without UV light source |
With UV |
without UV |
Leave us Message